Troubleshooting
Emergency mode
Hot water for emergencies
If a fault occurs in the control system or in the components of the Compact P2, and the appliance stops as a result, it cannot produce domestic hot water.
If the installer cannot come right away or the malfunction occurs outside opening hours and so you cannot contact the installer, there is a possibility to get hot water by putting the appliance in emergency mode.
The emergency mode button is located behind the large door.
Emergency mode has three settings:
I - Auto: Additional electric heating is controlled by the appliance control system (default setting)
0 - Off: The supplementary electric heater is switched off and cannot be switched on via the appliance control system.
II - Manuel: The supplementary electric heater is switched on and cannot be switched off via the unit control system (do not switch on if there is no water in the tank).
In manual emergency mode, the water temperature can reach 75 °C, which can cause scalding, if you are not careful when switching on the hot water.
Central heating in emergency mode
If a fault occurs in the control system or components of the AIR heat pump, and the heat pump stops as a result, the house cannot be heated by the central heating system.
If the installer cannot come immediately or the malfunction occurs outside opening hours, and therefore you cannot contact the installer, there is the possibility of heating the house by putting the AIR heat pump into emergency mode.
The emergency mode button is located behind the large door.
Emergency mode has three settings:
I - Auto: Additional electric heating and the ciculation pump are controlled by the appliance control system (default setting)
0 - Off: The supplementary electric heater is switched off and cannot be switched on via the appliance control system.
II - Manuel: The supplementary electric heater and ciculation pump are switched on and cannot be switched off via the unit control system.
The emergency mode for the circulation pump has three settings:
I - Auto: The circulation pump is controlled by the unit's control system (default setting).
0 - Off: The circulation pump is switched off and cannot be switched on via the appliance control system.
II - Manuel: The circulation pump is on and cannot be switched off via the unit control system.
When the supplementary electric heater is in I or II, the circulator must be in the same position.
In manual mode, the supply temperature can reach 40 °C.
Domestic hot water
Errors and solutions household hot water
| Problem | Possible cause | Solution |
|---|---|---|
| The appliance does not produce enough domestic hot water. |
The filters may be clogged so that too little air enters the unit.
This can happen if the filters are not changed often. This can happen if the unit has been in operation during the construction process and the filters are full of dust and dirt. |
Change the filters and, if necessary, set the filter replacement period to a shorter interval. |
Central heating
Errors and solutions central heating
| Problem | Possible cause | Solution | The thermostats call for heat, but the heat pump does not start. |
During the spring and autumn transition period, some room heaters may call for heat but the heat pump will not start. This may be because the temperature in the return air is warm enough compared to the temperature set in the control panel. That is, the return air is an average of the room temperature in the room, as some rooms are hot and others are cold. Because the ventilation section considers the average temperature in the house high enough, it blocks the operation of the heat pump. It does this to save energy and to prevent the ventilation part and the heat pump part from working against each other. |
If you still want to heat some rooms even though the average temperature in the house is warm enough, you can activate this function below: Settings / Central heating in the menu: Cooling and heating at the same time. This means that the cooperation between the ventilation part and the heat pump part stops, and if there is a need for heat in certain rooms, the heat pump will start even if the ventilation part detects that the house is warm enough. |
|---|---|---|
| Electric supply is switched on a lot or all the time. | The heat pump is not working properly, which could have several causes. |
- Check that there is no ice in the surface of the evaporator in the outdoor unit. This hinders air flow. Perform a manual defrost. - Check that the evaporator surface in the outdoor unit is not clogged with leaves and other debris that may prevent the passage of air. Clean the evaporator surface. - Check that the hoses between the outdoor unit and the indoor unit are well insulated to prevent excessive heat loss. - Check that there is good flow in the circuit between the outer part and the inner part. |
| AIR has high power consumption | One should expect electricity consumption to be higher than expected in the first year. This is quite normal because the house needs to dry. The higher humidity in the first year means it takes more energy to heat the house. This may also be because the heat pump is not working optimally for various reasons. |
- Check that there is no ice in the surface of the evaporator in the outdoor unit. This hinders air flow. Perform a manual defrost. - Check that the evaporator surface in the outdoor unit is not clogged with leaves and other debris that may prevent the passage of air. Clean the evaporator surface. - Check that the hoses between the outdoor unit and the indoor unit are well insulated to prevent excessive heat loss. - Check that there is good flow in the circuit between the outer part and the inner part. |