Data Data
SEC* average climate -40.6 kWh/(m2 .a)
SEC* cold climate -79.5 kWh/(m2 .a)
SEC* warm climate 15.7 kWh/(m2 .a)
SEC class A
Type Two-way ventilation device for homes
Drive type Variable-speed drive
Heat recovery type Recuperative (countercurrent heat exchanger)
Thermal efficiency of heat recovery 90%
Maximum flow rate 398 m3 /h (100 Pa)
Electrical power consumption of fan drive, including any motor control equipment, at maximum flow rate 175,1 W
Sound power level (LWA) 48 dB(A)
Reference flow rate 0.077 m3 /s (278.6 m3 /h)
Reference pressure difference 50 Pa
SPI 0.23 W/(m3 /h)
Central demand management 2,04
Maximum internal leakage 1,82%
Maximum external leakage 1,12%
Visual filter warning An alarm appears on the control panel when the filters need to be changed. To maintain the performance and energy efficiency of the appliance, it is very important to change the filters regularly.
AEC - annual electricity consumption 253 kWh/yr (100 m)2
AHS** average climate 4630 kWh (100 m)2
AHS** cold climate 9057 kWh (100 m)2
AHS** warm climate 2093 kWh (100 m)2

∗ specific energy consumption - ∗∗ annual heating savings

Ecodesign data - Hot water production

Data Data
Consumer profile, boiler XL (X-large)
Energy efficiency class A+
Energy efficiency for water heating - average climate 126%
Annual electricity consumption - average climate 1326 kWh/year
Temperature settings on the thermostat 10 - 65 °C
Sound power level LWA 50 dB(A)
The boiler can operate outside periods of peak load (Smart-grid) YES
Assembly, installation and maintenance guidelines See installation instructions
Energy efficiency for water heating - cold climate 126 %
Energy efficiency for water heating - warm climate 126 %
Annual electricity generation - cold climate 1326 kWh/year
Annual electricity production - warm climate 1326 kWh/year

Ecodesign data - AIR9

MODEL AIR9
Air-to-water heat pump YES
Water-to-water heat pump NO
Ground/water heat pump NO
Low-temperature heat pump YES
Equipped with additional heating YES
Heat pump combination heating NO
Temperature control:
Model CTS602
Class 2
Contribution to seasonal energy efficiency for space heating 2 %
ITEM SYMBOL VALUE UNIT
Nominal heat capacity (*) 5,21 kW
Declared capacity for heating at part load at an indoor temperature of 20 °C and an outdoor temperature of Tj
Tj = -7 °C Pdh 4,79 kW
Tj = +2 °C Pdh 2,88 kW
Tj = +7 °C Pdh 1,90 kW
Tj = +12 °C Pdh 2,12 kW
Tj = bivalent temperature Pdh 5,21 kW
Tj = operating temperature Pdh 0 kW
Bivalent temperature Tbiv -10 °C
Degradation coefficient Cdh 0,94 - 0,99
Power consumption in modes other than active mode
Off mode POFF 0,01 kW
Thermostat off mode PTO 0,005 kW
Standby mode PSB 0,010 kW
Crankcase heater mode PCK 0,000 kW
Other items
Capacity check: Variable-speed compressor
Variable adjustment of indoor temperature
Fixed inland water flow
Fixed outdoor water flow rate
Sound power level, indoors LWA 46 dB
Annual energy consumption QHE 1464 kWh
ITEM SYMBOL VALUE UNIT
Seasonal energy efficiency for space heating ŋs 206 %
Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20 °C and outdoor temperature Tj
Tj = -7 °C COPd 3,20
Tj = +2 °C COPd 4,95
Tj = +7 °C COPd 6,53
Tj = +12 °C COPd 9,69
Tj = bivalent temperature COPd 2.83
Tj = operating temperature COPd 0
For air-to-water heat pumps:
Limit temperature
TOL -22 °C
Limit temperature of heating water WTOL 45 °C
Additional heating
Nominal heat capacity Psup 6 kW
Type of energy input Electric
For air-to-water heat pumps:
Nominal air flow, outdoor
3000 m3/h