Product data

EU/EC declaration of conformity

Ecodesign data - Ventilation

Data Data
SEC* average climate -40.6 kWh/(m2 .a)
SEC* cold climate -79.5 kWh/(m2 .a)
SEC* warm climate 15.7 kWh/(m2 .a)
SEC class A
Type Two-way ventilation device for homes
Drive type Variable-speed drive
Heat recovery type Recuperative (countercurrent heat exchanger)
Thermal efficiency of heat recovery 90%
Maximum flow rate 398 m3 /h (100 Pa)
Electrical power consumption of fan drive, including any motor control equipment, at maximum flow rate 175,1 W
Sound power level (LWA) 48 dB(A)
Reference flow rate 0.077 m3 /s (278.6 m3 /h)
Reference pressure difference 50 Pa
SPI 0.23 W/(m3 /h)
Central demand management 2,04
Maximum internal leakage 1,82%
Maximum external leakage 1,12%
Visual filter warning An alarm appears on the control panel when the filters need to be changed. To maintain the performance and energy efficiency of the appliance, it is very important to change the filters regularly.
AEC - annual electricity consumption 253 kWh/yr (100 m)2
AHS** average climate 4630 kWh (100 m)2
AHS** cold climate 9057 kWh (100 m)2
AHS** warm climate 2093 kWh (100 m)2

∗ specific energy consumption - ∗∗ annual heating savings

Ecodesign data - Hot water production

Data Data
Consumer profile, boiler XL (X-large)
Energy efficiency class A+
Energy efficiency for water heating - average climate 126%
Annual electricity consumption - average climate 1326 kWh/year
Temperature settings on the thermostat 10 - 65 °C
Sound power level LWA 50 dB(A)
The boiler can operate outside periods of peak load (Smart-grid) YES
Assembly, installation and maintenance guidelines See installation instructions
Energy efficiency for water heating - cold climate 126 %
Energy efficiency for water heating - warm climate 126 %
Annual electricity generation - cold climate 1326 kWh/year
Annual electricity production - warm climate 1326 kWh/year